MSF: Crankcase failure
What happened
The Marine Safety Forum has published Safety Alert 21-19 relating to a crankcase failure. A vessel suffered a crankcase failure on one of four diesel generators, which resulted in two small fires and excessive damage to the pistons, con-rods, and the engine block. Fortunately, no personnel were injured during this event and due to the swift actions from the crew and additional barriers already in place, the situation was quickly and effectively controlled, and any potential secondary damage to surrounding machinery was prevented.
What went right
• The vessel had plexiglass guards surrounding the diesel generators which meant that there was less secondary damage than normally results from these types of failures;
• No-one was working nearby – by design and planning. The Chief Engineer’s standing orders required that no prolonged work scopes would be carried out alongside a running diesel generator;
• The Emergency Response Plan was effectively implemented by the well trained and drilled crew.

What went wrong?
After investigation, it was found that a main bearing had worn out. It had been very hot at some point. When the main bearing cap was dismantled the upper bearing was located in the bearing cap, with the result that the bearing had been turning on the crankshaft. This blocked the lubrication hole on the main bearing, and the con-rod at one cylinder received its oil supply from this main bearing. This meant that this cylinder con-rod also lost its oil supply. This was probably the main failure from the start. The investigation also noted that:
- The diesel generator had recently undergone a major overhaul;
- The maintenance of the diesel generator was in order as per manufacturers instructions;
- The running hours were well below manufacturers guidance.
Members may wish to refer to:
Safety Event
Published: 9 December 2021
Download: IMCA SF 34/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.