MSF: Engine damage after routine maintenance
The Marine Safety Forum (MSF) has published Safety Alert 21-09 relating to engine damage following routine maintenance.
What happened
On an offshore platform supply it became necessary to stop one of the engines due to a high temperature alarm. The vessel was alongside a platform in DP mode at the time. Cargo operations were stopped, and the vessel moved to a safe location before the engine was stopped.


What was the cause?
Upon inspection, damage was found in a valve gear assembly of a cylinder. Investigation showed that 86 running hours before the incident, valve adjustments had been carried out. When removing the cylinder cover, small metal particles and partial destruction of the exhaust valve tappet tip was found. The evidence available indicated that the locking nut of the adjusting screw from the exhaust rocker arm (that regulates the clearance of the exhaust valve) had become loose. The most likely cause of this is that when reassembling, the locking nut had not been tightened as per the manufacturer’s requirements.
Actions/lessons learned
- Ensure that maintenance is conducted according to the manufacturer’s requirements;
- After maintenance always carefully (double) check that all parts are properly (re-)assembled;
- Always check torque using a torque wrench as per manufacturers manual.
Members may wish to refer to:
Safety Event
Published: 9 June 2021
Download: IMCA SF 16/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.