MSF: Hand Injury Sustained During Routine Checks
The Marine Safety Forum (MSF) has published Safety Alert 21-13 relating to a hand injury sustained during routine activities.
What happened?
During routine weekly checks, someone was performing tests for the emergency generator. The MSF reports that he approached the generator to investigate an abnormal noise coming from the cooling fan, and his fingers were struck by the fan blades, and he sustained an injury to three of the fingers on his right hand.
Why did it happen?
The MSF’s correspondent notes the following:
- Unsafe, complacent behaviour;
- Lack of situational awareness – he placed his hands in an area with a partly exposed rotating part;
- The injured person was working alone;
- The fan was partly unprotected.

Actions and lessons learned
- Modifications were made to the fan guard of the emergency generator to avoid any possibility of touching the fan – and warning signs were posted;
- Further training for crew in “Situational Awareness”;
- A fresh look at hand safety in general:
- Always be aware of where your hands are at all times;
- Always wear the appropriate PPE (including the right gloves for the job);
- Always identify all potential hand hazards (i.e., line of fire, pinch points) and take the appropriate mitigating steps during the planning stage of a job;
- Always use Risk Assessment and Toolbox Talk as appropriate in all tasks, whether formal or informal;
- Risk Assessment should be specific and identify the hazards and the Toolbox Talk should include discussion of the task at hand with those involved;
- If you don’t understand, ASK!! Don’t start the job, however simple or complex, unless you understand what you are supposed to be doing.
Please STOP and think!! Watch your hands – you’ve only got one set!!
Members may wish to review:
- Are you prepared to work safely? Short video Line of fire
- IMCA poster on hand safety
- Hand injury when caught in machinery
- Finger injury caused by incorrectly secured console cover
- Hydraulic sample extruder – finger laceration
Safety Event
Published: 22 September 2021
Download: IMCA SF 26/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.