MSF: person injured falling between decks
The Marine Safety Forum (MSF) has published Safety Alert 23-06 relating to someone who fell 2m between decks on an AHTS (Anchor handling vessel) alongside in port.
What happened
The injured person fell approximately 2m from A-deck to the port chain chute on the main deck. The injured person was conscious but disoriented and had a small cut to the head. First aid was given and the person was transferred to hospital. The injured person suffered one broken vertebrae, several broken ribs, a fractured wrist, a cut to the back of the head and internal bruising to the kidneys.
Findings
Inspection of A-deck found that the safety chain was not in place. Safety chain could not be confirmed to be in place as it was found in the down position with a link missing. A carabiner was still in place at one end and a welded link in place on the other. Missing link on welded end could not be located.
The MSF report also notes the following:
- The injured person – an experienced (30 years offshore) client’s representative – was fully rested prior to the Incident and was not distracted at the time;
- The injured person was off duty at the time and had proceeded to the winch hanger to check on activity on deck and have a cigarette, use his mobile phone, and return to his cabin;
- The grating on A-deck has a raised edge approximately 76mm high that is highlighted with yellow paint. The injured person may have tripped over it. As he was “off shift” no PPE was being worn;
- It could not be determined if the safety chain at the edge of the deck grating was actually in place prior to the incident.


Actions
- Improved barriers to be installed around port and starboard gypsies;
- Update Shipboard/Contractor Familiarisations and Inductions to include identification of restricted and working areas;
- Replace all chain barriers with gates or solid railings. All restricted/working areas to be identified and signage posted. Temporary chain barriers and signage were put in place as a short term measure until solid hand rails could be fabricated and fitted;
- Install barriers and signage to clearly identify working areas.
Members may wish to refer to:
Safety Event
Published: 3 August 2023
Download: IMCA SF 19/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.