Near miss during helicopter operations
What happened?
During helicopter flight boarding, a member of the crew crossed a hard barrier (stairway access chain) with a restriction sign and approached the flight deck from the aft stairway while boarding activities were ongoing on the forward side.
A member of the helicopter emergency response team – an offshore helideck assistant – attempted to intervene by shouting. The warning did not prevent the crew member from approaching the helicopter from the uncontrolled or prohibited direction and from passing beneath the tail rotor blades.
The HLO was controlling boarding from the forward stairway. From CCTV records, it is estimated that distance between the crew member and the rotor tail was approximately 1.5-2m. No injury occurred during the event.
What went wrong? What were the causes?
- The crew member did not follow safety rules on helideck (i.e. to NOT pass under the tail rotor);
- The HLO lost control of situation;
- Employee removed a safety barrier (chain);
- There was no signalman available to guard the safety barrier (chain);
- Employee was not escorted when ascending the stairs.
Some contributory factors identified by our member were:
- The helideck readiness check was performed in an ineffective way;
- The helideck check list did not include a line item concerning how to correctly fold the foldable handrails in advance of helicopter landing and take-off. During the investigation, the foldable handrails had been found folded in the wrong direction;
- Passenger embarkation had been delayed by handover.
What lessons were learned?
- Human Errors and Safety Barriers: human error can reduce or even eliminate the effectiveness of a physical barrier (chain, handrail, safety tape, etc.). Human error occurs when an incorrect action takes place, but the person involved believes the action to be correct. A human error involves an incorrect judgment.
- In this specific case the passenger demonstrated full awareness of the safety barrier rules; however, the misleading evaluation of being left behind by other passengers allowed the passenger to make the mistake of removing the barrier. He was convinced that he was authorized to reach the helideck as part of the boarding passengers and the removal of the barrier was not thus perceived by the individual as a safety violation.
- The human factor should always be considered during the design of safety systems.
What actions were taken?
- Changes to risk assessments, procedures and safety management systems (SMS) are omitted as understood;
- During helicopter briefing, ensure passengers understand reasons for following the rules and the consequences for deliberately not following them;
- Improve clarity on access route to use (e.g. flashing lights or directional signs) to identify the access in use for helicopter embarkation and provide dedicated embarkation/disembarkation facilities for personnel and baggage.
Members may wish to refer to:
- Fatality and multiple injuries: flash fire incident onboard pipelay barge [same immediate cause, a passenger, for reasons of haste and anxiety, acted outside of his normal behaviour and put himself in considerable danger]
- Near miss: potential fall through CTV hatch [similar causes, including passenger compromising his own safety by going back on board the CTV without alerting the crew]
Safety Event
Published: 30 January 2020
Download: IMCA SF 03/20
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.