Near-miss: Potential fall when TMS protection gate came loose
A member has reported a near miss potential fall and dropped object incident in which a protection gate on a Tether Management System (TMS) was almost lost. The incident occurred when crew were working on the top on of an ROV, using cut-out holds on the TMS protection gate itself. The two dogs on top of the protection gate became dislodged from their receptacles; whilst the gate was still secured by bolts and ‘R’ clips at the bottom, it fell into the inside of the TMS. The personnel working managed to hold onto one of the main load bearing posts of the TMS. Full harness and fall arrestor equipment was being used and a permit to work for working at heights had been issued. There were no injuries or damage to equipment.
Further investigation revealed that when downward force was applied to the gates via the cut-outs, the gate became dislodged.
Members are encouraged to make a careful check of this kind of TMS protection gate to ensure they are secured by the top pins. If they tend to come out while downward force applied, then the top pins should be changed immediately. The top pin which is secured to the gate can be modified such that it won’t dislodge easily.



Safety Event
Published: 4 September 2012
Download: IMCA SF 09/12
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.