Skip to content

Oxygen near-miss

A member reports the following near miss whereby a worker was observed blowing oxygen into the welding hood of a co worker who was welding on a pipe. This was stopped immediately.

All three occupants of the tented area where work was taking place were interviewed and stated that the welder’s hood was ‘fogging up’ and that the oxygen was being used to keep the lens clear. It was then explained to them that the potential existed for a flash fire in the welder’s clothes, under his hood and in his lungs as a result of the high concentration of oxygen in those areas.

The company involved has taken the following actions:

  • Immediate stoppage of work;
  • Instructions to the prime contractor to conduct a safety ‘stand down’ with its sub-contractor immediately and with its own key personnel when they returned to work the following Monday;
  • Inclusion of this subject matter in site-specific training for all newly employed workers on the project;
  • Instructions to other sub-contractors doing similar work to have safety ‘stand downs’ to get this important message across.The company notes that although oxygen in normal concentrations is necessary to sustain life, it can also be potentially hazardous in concentrations above normal breathing amounts or in conditions where high levels of heat or a major ignition source are present.

    The company has restated the importance making clear potential hazards at each worksite through training and familiarisation and noted the danger of assuming awareness of ‘obvious’ hazards.

Safety Event

Published: 1 January 2004
Download: IMCA SF 01/04

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.