Safety Events
Diver’s lost gas incident
A member has reported a lost gas incident that occurred with two of its divers on a third party vessel. They do not normally dive from this vessel and were […]
Incorrect pressure-rated manifold fitted to diver’s bail-out
A member has reported an incident in which a manifold rated to 232 bar was fitted to a twin cylinder 300 bar bail-out. The manifold in question had no pressure […]
Incident involving a McKissick N419 snatch block
IMCA recently received notification of an incident involving a particular type of snatch block, which could be knocked apart if the bolt and hairpin were removed and the block left […]
Faulty directional flow arrow on valve
A member has reported the following safety issue concerning incorrectly machined valves. During general maintenance on a diver’s emergency gas manifold which was fitted in an air diving basket, a […]
Regulator fire
This incident was originally included in safety flash 11/03, but the flash is being reissued in the light of additional feedback on the recommendations previously given. The earlier version has […]
Near-miss involving diver’s neck dam
We were recently provided with and issued details of a ‘high potential’ near-miss incident involving failings in a saturation diver’s personal protective equipment. This information was issued as part of […]
Loss of mooring chain to FPSO
A planned ‘routine’ maintenance operation was in progress, to individually move each of eight anchor chains, to a pre-arranged plan, to ensure that the chain links were not subject to […]
Follow-up to Toxic gas emission from transponder (lithium batteries)
Further to the information provided in safety flash 01/03 (Follow-up to Toxic gas emission from transponder (lithium batteries)), Kongsberg Simrad has now updated its transponder safety information. This can be […]
Internal explosion within 12V forklift battery
A forklift battery was found to be flat and it was changed out with a replacement that was held onboard and tested per procedures, the forklift was also function tested […]
Airline coupling failure
We have received the following report of an incident which occurred during internal cleaning operations in a produced water de-gasser which was being undertaken by two contract cleaners. This vessel […]
Topic working with tubulars – Incident report
While carrying out backloading operations at a rig, a crewman suffered a lost time injury. The operation being carried out at the time was the movement of tubulars to make […]
Filtration materials
Please see the attached safety notice from Divex regarding filter materials for use in breathing air compressors.
Fire inside Falcom steamer
We have received a report of an incident which began when a night cook baker, returning to the galley after his break, smelt burning. He then noticed that there was […]
Incident involving a crane boom
We have received a report of an incident whereby a crane boom fell from an angle of 45° onto its rest. There was no one in the crane at the […]
Diver fatality: Underwater explosion
A member has advised of a recent fatality, involving an experienced diver, which occurred during underwater cutting operations as part of a well stub removal project. The site conditions and […]
Fatality: Fall from height arising from a failure to use personal protective equipment
We have received the following incident report, involving a fall from height from an offshore platform. A contractor was working on the skimmer level of an offshore platform, approximately 10½ […]
Near-miss: Modification of machinery
A member has advised of the following near miss. A mechanic was working on a jet pump when a bracket holding the jet hose failed. The bracket was being used […]
Machine guarding
Employee exposure to unguarded or inadequately guarded machines is prevalent in many workplaces. Amputations are one of the most severe and crippling types of injuries in the occupational workplace. All […]
Slips, trips and falls resulting from loose cables and hoses on walkways
A member has recently issued advice to its employees concerning slips, trips and falls. It notes that international review of incidents reveals that a substantial percentage of incidents are caused […]