What happened The United States Coast Guard (USCG) has published Safety Alert 13-17 relating to Fixed CO2 fire extinguishing systems. This alert follows discovery of critical deficiencies in the fixed […]
A new IMCA website has launched - www.imca-int.com -
this site remains available temporarily for access to the following:
Elections |
Membership Applications |
Safety Statistics Submissions
IMCA safety flashes disseminate important information on incidents and potential hazards and the lessons learnt from them that can help prevent incidents occurring elsewhere in the industry.
Individual safety events are available individually online, tagged and searchable, while the traditional PDF collections are also available for download.
All members are encouraged to contribute relevant safety-related information – please visit our Safety Flash Reporting page for details on the submission process.
Nicholas Hough
Consultant - Safety and Security
Contact
What happened The United States Coast Guard (USCG) has published Safety Alert 13-17 relating to Fixed CO2 fire extinguishing systems. This alert follows discovery of critical deficiencies in the fixed […]
During two recent vessel inspections Coast Guard marine inspectors participated in and witnessed occasions where the testing and maintenance of a COâ‚‚ system resulted in serious safety threats that could […]
A member has reported an incident where there was an elevated level of COâ‚‚ in the divers reclaim breathing gas during saturation diving operations. A dive team was performing diving […]
A member has highlighted a potential gap in safety awareness which may be of interest to members. One of their vessels has a CO2 flooding system activation point within the […]
The United States Coast Guard has published a report regarding an engine room fire in a vessel. The safety alert addresses the location of fire suppression system pressure switches aboard […]
The Marine Safety Forum (MSF) has published Safety Flash 11-31 regarding a ‘routine’ inspection of a vessel’s COâ‚‚ fire fighting system. It was noticed that the engine room COâ‚‚ isolating […]
The United States Coast Guard (USCG) has published Alerts 10(a)-10 abd 10(b)-10 regarding the failure of a CO2 fire-fighting system during a fire in a machinery space on board a […]
The UK Marine Safety Forum (MSF) has published the enclosed safety flash concerning the safety pins used for transporting and disabling COâ‚‚ cylinders.
A member has reported an incident involving the contamination of a diver’s breathing gas. CO2 contamination was found to be present in three cylinders of a diver’s breathing gas (96/4%). […]
IMCA has learned of the following incident whereby an unexpected hazard arose when stowing refrigerated stores. A vessel was in the process of mobilising for a prolonged spell offshore and […]