Further to the details provided in IMCA Safety Flash 03/05 (Incident involving Cameron high pressure accumulator) regarding high pressure accumulators, IMCA has been advised that this incident investigation is still […]
A new IMCA website has launched - www.imca-int.com -
this site remains available temporarily for access to the following:
Elections |
Membership Applications |
Safety Statistics Submissions
IMCA safety flashes disseminate important information on incidents and potential hazards and the lessons learnt from them that can help prevent incidents occurring elsewhere in the industry.
Individual safety events are available individually online, tagged and searchable, while the traditional PDF collections are also available for download.
All members are encouraged to contribute relevant safety-related information – please visit our Safety Flash Reporting page for details on the submission process.
Nicholas Hough
Consultant - Safety and Security
Contact
Further to the details provided in IMCA Safety Flash 03/05 (Incident involving Cameron high pressure accumulator) regarding high pressure accumulators, IMCA has been advised that this incident investigation is still […]
A member has reported a fatality which occurred during preparation of surfaces for welding. A welder was using an angle grinder for the preparation work when the disk of the […]
A member has reported that a saturation diver in 120m of water, preparing to move a pipeline lay-down head (LDH) using a lift bag, was struck in the back by […]
A member has reported an incident where the stern of a diving support vessel suffered fire damage caused by flaring gas from a rig vent. The vessel was secured to […]
A member has reported the following fatality which occurred during movement of drill pipes. Personnel were engaged in the task of lifting bundles of 12cm drill pipe by crane from […]
IMCA has been passed the attached safety alert (2030 Rev. 1) issued by Cameron, which related to an incident involving a high pressure accumulator.
A member has reported an incident where a diver received a burn to his hand during use of underwater cutting equipment. The company concerned has advised its employees as follows. […]
IMCA has received a report of a very serious threat to the safety of a gas production platform, caused by rafts containing bundles of lit cooking gas tank sets. These […]
There have been previous safety flashes relating to ‘Grimsby’-type buoys, and members are asked to note this further incident. Guidance relating to ROV operations is available in Plastic spherical air-filled […]
During a recent diver inspection, repair and maintenance programme undertaken by one of our members, one of the identified tasks was the replacement of a defective temperature sensor mounted in […]
A worker was cutting an aluminium roof using a grinder when the wheel came apart, striking the worker in the face and causing serious injury between his upper lips and […]
IMCA has received a report of an incident wherein a worker’s finger was crushed. The injury occurred during an operation when a large heavy axle, weighing some 250kg, was being […]
Whilst reviewing its test and repair procedures for transponders, a member has reported that a serious flaw was discovered in the pressure relief mechanism in two out of three Kongsberg […]
There has been a significant spread of MRSA (the ‘super bug’) in hospitals in recent times and it is possible that it could become a problem in the future for […]
A member has reported a high potential near-miss which occurred during a regular field maintenance operation which was taking place from a lift boat in 7½ metres of water, whereby […]
An incident has been reported to IMCA which, although relating to a road incident, provides an important reminder in relation to the securing of loads. During transportation of five empty […]
IMCA has been advised of a fire on a vessel which destroyed a substantial amount of diving equipment. The photographs demonstrate the level of heat generated in a short time […]
A member has reported a high potential incident (HIPO) which occurred during the recent mobilisation of a vertical lay system (VLS) at the quayside. Fortunately, no one was injured. However, […]
We have received information on a fatality which occurred when a person fell from a high voltage transmission tower whilst wearing the appropriate PPE (fall arrest system). The full incident […]
During delivery of an offshore container to a warehouse, a large metal object was observed lying on top of the container by a worker on a higher floor. The object […]
2255 post(s)