Person injured going down ladder
What happened
A person was descending the fixed ladder of a carousel manhole. He lost his footing on the last three rungs, approximately 87 cm from the flooring. Falling backward, his helmet came off, and his head struck the edge of a steel structure and he was injured. Immediate medical attention was provided on board by the ship’s medic. A follow-up medical assessment was subsequently organized ashore, where he received stitches.
Possible causes (as indicated by the member)
- Inattention: Misjudgement of the remaining steps while descending the ladder contributed to the slip;
- Improper PPE Use: The IP did not properly secure the chinstrap of his safety helmet, causing it to fall off during the incident;
- Inadequate Working Environment: Poor lighting at the bottom of the carousel manhole may have contributed to the incident;
- Lack of Signage: No signage was present to indicate the mandatory use of safety harnesses for work in the carousel’s manhole.



Actions taken
- Improved lighting in the area;
- Be aware of your working environment and keep a focus when you are moving – watch out for complacency;
- Ensure that all PPE, especially the helmet, is worn and secured correctly.
Members may wish to refer to:
Safety Event
Published: 22 January 2024
Download: IMCA SF 02/24
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.