Pipe under tension on a reel
A member has relayed a report of an incident involving a reel containing pipe under tension at a third party’s onshore facility. An employee, unaware that the pipe was under tension, removed the ratchet strap securing the pipe on the reel. When the tension was released, the pipe sprang out and struck the employee above the left eye, causing a wound which required subsequent medical treatment.
There was a caution label warning that the pipe was under tension. However, this was on the flange of the reel and not clearly visible.
The following actions were recommended:
- Tensioned pipes should be tied off/secured using either a mechanical ‘U’ clamp or pipe clamp with a ratchet strap (or rigging) being used as a back up.
- Any warning signs should be attached to the pipe end or near the securing mechanism such that they are clearly visible to all personnel who will be handling the reel and pipe.
Photographs relating to this incident are shown below.



Safety Event
Published: 16 February 2007
Download: IMCA SF 01/07
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.