Radio interference from damaged equipment affects other vessels
What happened
On a pipelay barge, radio frequency interference to the vessel’s GNSS systems was reported by a surveyor. There was only one other vessel alongside. This vessel was contacted with a request to switch off any transmitting devices.


On that vessel, bridge systems with transmittal capabilities were switched off, and the pipelay barge GNSS functionality was restored. Vessel crew started troubleshooting, but the reason could not be identified and technical support from shore was requested.
What was the cause?
The shore service team used radio frequency (RF) detection and spectrum analysis equipment to detect and analyse RF signals transmitted by various sources, after which it was identified that the interference issue was caused by a factory-fitted SAILOR 150 Fleet Broadband which was not in use, but not disconnected.
The radio frequency interference came from a failed connector panel of SAILOR 150 Fleet Broadband System. This caused an outage of GNSS positioning systems for the surrounding vessels in close vicinity.
Recommendations
- Failed equipment can transmit a radio signal which can interfere with the communication or navigational equipment nearby;
- Check for any similar equipment onboard that is not in use, but not disconnected or powered down – removal may be worth consideration.
Members may wish to refer to:
- GPS antenna problems (2008)
- Potential interference of VHF-FM radio and AIS reception
- IMCA S 024 M 242 Guidance on satellite-based positioning systems for offshore applications
- Information Note id 1436 GNSS interference, jamming and spoofing [April 2019]
- Information Note id 1525 GPS systems – Warning of interference[October 2020]
Safety Event
Published: 28 January 2022
Download: IMCA SF 03/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.