Snaking air hose
A mechanic had started a deck air compressor, when the sudden delivery of pressurised air through the delivery hose caused momentary snaking of the hose. The mechanic acted in a calm manner and switched off the compressor immediately. Fortunately no one was positioned close to the coiled hose, so nobody was injured. Nothing was damaged.
The snaking hose had the potential to cause injury to personnel on deck.
During investigation, it was also noticed that the isolation valve’s handle was missing.
Before starting the compressor, the mechanic had not checked the delivery valves to confirm that these were closed. The missing valve handle had not been reported.
The company involved has issued a safety reminder to its personnel as follows:
World-wide, many serious accidents occur due to snaking hoses. It is, therefore, necessary to follow some simple safety precautions efore and during use of any compressor:
- Before starting up a compressor, ensure that all air delivery valves are shut;
- Check that all valve handles are secured in place;
- Check condition of hose for any physical damage;
- Check all hose line clamps for tightness, to ensure non inadvertent parting of hoses while in use;
- Check all hose connections are secured with safety rope, to prevent a whiplash/snaking effect if parted;
- Ensure insurance wire is fixed on all quick-release couplings to prevent inadvertent parting of couplings while in use;
- Ensure all hose lines are anchored/secured with rope to fixed structures, to prevent a whiplash effect if parted;
- Know where the compressor’s ’emergency stop’ button is situation and how to use it;
- After use, ensure that air-delivery valves are closed and that the delivery hose is coiled and kept safely;
- Report all unsafe acts and unsafe conditions.
Safety Event
Published: 1 March 2004
Download: IMCA SF 02/04
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.