SOPEP oil booms

One of our members has alerted us to a problem with one type of SOPEP oil boom – type SMB40.

SPOEP oil booms are normally manufactured using blown polypropylene as the absorbing membrane, contained within an outer cover manufactured and sewn together using polypropylene. Whilst polypropylene will begin to melt at 160°C, it will not support combustion.

Type SMB40 oil booms have been found to be covered in nylon, which will burn rapidly when in contact with an ignition source.

The member involved has instructed all of its vessels to remove these booms from service and has informed us that the manufacturer has withdrawn this type of boom from offshore sale and use.

Safety Event

Published: 1 November 1999
Download: IMCA SF 06/99

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.