Skip to content

Subsea oxy-arc cutting – risk of explosion

The International Association of Oil & Gas producers (OGP) has published the attached safety flash (OGP safety alert number 227), entitled Subsea oxyarc cutting – risk of explosion. The information can also be found at info.ogp.org.uk/safety.

The safety flash recommends that double isolations that perform a complete break in both poles of the circuit should be used between the surface generator and the diver to form a more effective and dependable isolation.

Members are reminded that subsea oxy-arc cutting operations are addressed in IMCA D 003(Guidelines for oxy-arc cutting) and IMCA D 022 – (Guidance for diving supervisors– chapter 12, section 15).

Guidance contained within the diving supervisor’s manual includes that the knife switch should be mounted in such a way that it cannot fall or be knocked into the on position. Ideally it should be a double pole switch enclosed in a protective wood or plastic box with only the handle showing.

Members are also reminded that both IMCA D 003 and IMCA D 022 are currently under review.

Safety Event

Published: 15 December 2010
Download: IMCA SF 08/10

IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.