Surface decompression near-miss
What happened?
During surface decompression, following a SURDO2 42msw/40min dive, the depth of the chamber was unintentionally decreased from 12msw to 5msw forty minutes into the decompression. Immediately after this was discovered, Treatment Table 5 was initiated. The divers did not present any symptoms before, during or after the incident.




What was the cause?
Investigation concluded that the two main causes of the failure were:
- The exhaust valve was not completely closed; no technical faults on the system;
- The dive supervisor running the decompression was teaching new divers chamber operation and got distracted. Under local regulations applicable in this incident, it is the supervisor who is responsible for running the chamber.
Corrective action/lessons learned:
- The root cause was the dive supervisor running the decompression, without anyone supervising him (no human second barrier);
- Procedures/manuals were updated to highlight that a diver runs the chamber during decompression, and the dive supervisor controls the diver;
- The chamber panel was modified with a visual and non-mutable alarm for the venting;
- A visual alarm showing depth shallower than 12msw, and an additional camera for the SUPV to see the DDC chamber readings was installed.
Members may wish to refer to:
Safety Event
Published: 31 May 2022
Download: IMCA SF 13/22
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.