Transponder pressure relief system failure

Whilst reviewing its test and repair procedures for transponders, a member has reported that a serious flaw was discovered in the pressure relief mechanism in two out of three Kongsberg transponders tested. Such transponders are in common use across marine operations world-wide and it is possible that some could exhibit the same fault whereby internal pressure build-up would not be able to be vented automatically.

It appeared that the pressure relief mechanism was locked in place and would not operate, possibly due to an assembly fault by the manufacturer.

Pending detailed instructions from the manufacturer, the contractor instructed its personnel not to disassemble any such transponders.

Kongsberg has been exploring the matter, relating to the RPT model transponder (which went out of production in 2002) and has now issued a technical bulletin on the subject, a copy of which is attached.


IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.