UK HSE: Incident during rig decommissioning leads to fatality

The United Kingdom Health and Safety Executive (HSE) has published a press release relating to an incident whilst decommissioning a North Sea gas rig, in which one person died and another was seriously injured.

What happened

Two men were working as demolition operatives, also known as “Top Men”, undertaking the decommissioning and dismantlement of offshore structures which had been brought ashore. The two workers were removing an overhanging piece of metal pipework (known as a skirt pile), weighing in excess of 27 tonnes, from a gas rig jacket when it gave way. The pile struck the mobile elevating work platform (MEWP) containing the men, throwing them to the ground about 12 metres below.

One worker died at the scene and the other suffered serious life-changing injuries.

Where the workers fell
The skirt pile gave way and struck a mobile elevating work platform
Emergency services attended the scene following the incident

What went wrong

HSE investigation identified:

  • Serious failings with the planning and the risk assessment which did not adequately cover the planned works;
  • Shortcomings in supervision;
  • The company did not risk assess the skirt pile being removed as it was considered low risk. As a result there was no cutting plan or safe system of work for the skirt pile.
  • HSE noted that demolition, dismantling and structural alteration work must be carefully planned and carried out – HSE has guidance on this.
  • After the hearing, the HSE inspector noted: This incident, in an emerging industry, highlights the level of controls required to safely demolish what are large, dangerous structures. These standards were not met and tragically one life was lost, and another forever changed.

Members may wish to refer to:

Safety Event

Published: 23 October 2024
Download: IMCA SF 21/24

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.