Umbilical management – near miss
What happened
A diver was working with the barge crane to remove two sleepers from under a newly installed 16” x 45 ft (40cm x 13.5m) repair spool. The crane was rigged directly onto the sleepers to be moved. Once the sleepers cleared, the pipeline moved and rolled over a section of the divers umbilical. The diver discovered that his umbilical was trapped and was able to free it himself. Visibility was excellent, it was daylight, and the diver was able to move his umbilical over to a suspended section of pipe, and was unharmed.

What went right
- Both diver and supervisor were very experienced and were able to work very quickly on a solution;
- This was a decompression dive that did not exceed the planned bottom time.
What were the causes
- Procedural – no procedure existed for the sleeper removal, due to an oversight during the project planning phase;
- Human Performance – the diver did not recognize the line of fire umbilical management hazard;
- Human Performance – the Dive supervisor did not call an “all stop”, due to a lack of full procedural understanding. No MoC (management of change) was created.
Corrective Actions
- Develop a removal procedure to include the removal of the diver’s umbilical from the bottom, before starting the operation;
- Review with the entire crew the Umbilical Management process and sleeper removal procedure.
Members may wish to refer to
Safety Event
Published: 11 January 2023
Download: IMCA SF 02/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.