Uncertified lifting gear found in use
What happened
A number of shackles and other lifting equipment were observed in use onboard a vessel with no certification or inspection reports available. Some equipment was colour coded by the crew and deemed as being in good condition; other equipment was not included in the vessel lifting gear register, nor was it colour coded. Further investigation revealed that lifting equipment had been left onboard and not removed after the end of the previous project, on which client-supplied lifting equipment was used.

What was the cause
- Company lifting equipment inspection processes were not followed: “Authorized competent person to conduct the lifting gear inspection process on an 6 monthly basis with further issue of inspection report”;
- Client-supplied lifting gear was not removed from vessel, nor quarantined;
- This same equipment was not presented to the vessel lifting gear inspection onboard, conducted by the lifting inspection contractor;
- There was a lack of awareness of both relevant lifting equipment regulations and of local and corporate safety management system standards.
Actions taken
- An overall check of the lifting gear and relevant equipment was initiated and all identified non-compliant equipment was quarantined;
- Onboard discussion arranged for crew to better understand:
- There should be no use of lifting equipment unless it has been thoroughly examined, tested and certified;
- Colour coding of lifting gear or equipment should not be applied by crew without there being a relevant certificate or inspection report available.
- All lifting equipment available on board to be presented during testing and examination provided by competent authorized party.
Members may wish to refer to:
Safety Event
Published: 9 February 2023
Download: IMCA SF 04/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.