Uncontrolled movement of crane jib during inspection
A member has reported an incidence of uncontrolled movement of a crane jib during inspection operations. The crane boom/knuckle had been lowered to deck to enable access to the main hoist sheave for inspection and maintenance purposes. The crane was powered down and the operator was not in the cab. During the inspection there was an uncontrolled movement of the knuckle section along the deck of approximately 30cm towards the crane pedestal.
The hydraulic cylinders in the main boom were not fully closed when the crane was stowed in this position; therefore the weight of the jib was able to overcome the friction on deck and thus caused the movement of the knuckle head across the deck. At the time of the movement the inspector had been positioned close to the equipment in order to gain access on either side for a complete overview.


A number of key lessons were drawn from this near-miss:
- Conduct such inspections and ‘routine’ maintenance with the crane stowed in dedicated parking position i.e. crane crutch;
- Ensure that the main boom cylinders are fully closed to avoid uncontrolled movement of crane jib;
- Follow approved procedures and always fully brief third party personnel during a toolbox talk prior to commencing the operation;
- Follow and adhere to the permit to work system, review and risk-assess specific tasks;
- Ensure that a complete and thorough shift handover is conducted at all times and strive to identify any hazards while the job is in progress; . Barrier off work-site and ensure all personnel are aware of the potential hazards.



Safety Event
Published: 3 December 2008
Download: IMCA SF 17/08
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.