Underwater rigging failure
During the recovery of two 400kg buoyancy blocks from the seabed a swaged eye of a strop failed and one of the blocks rose uncontrolled to the surface. No one was hurt and there was no damage.
The eyes of the strop were made up in the usual way; i.e. with an alloy swaged sleeve. It had been under water for about 11 months, during which time the sleeve corroded causing the eye and wire to fail.
The contractor involved has suggested the following precautions should be taken:
- Do not plan to use alloy swaged rigging which may be left under water for long periods;
- Use extra caution when recovering subsea loads which may have alloy swaged eyes fitted. Check to find out how long the rigging has been submerged;
- Inspect alloy swaged eyes for pitting and other signs of corrosion before use – discard them if there is any doubt about their condition;
- Visually inspect rigging each time it is used.
Safety Event
Published: 1 January 1999
Download: IMCA SF 01/99
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.