Unexpected truck movement caused rigger to fall off a ladder
An unexpected movement of a container loaded truck during disconnection of the container’s rigging, caused a rigger to fall off a ladder leaning against the container. Two containers were being loaded onto a trailer truck using a mobile crane. The supervisor conducted the toolbox talk before starting work. The riggers removed the container’s rigging (chain hooks), using a ladder to access the connection points.
The first container was loaded without incident. The second container was loaded onto the trailer and the riggers began to remove the chain hooks whilst the supervisor and driver secured the twist locks. To access the 4th and last chain hook the rigger positioned the ladder against the rear of truck trailer. After securing the twist locks the driver went to the cab. He checked the side mirrors and could only see the supervisor, and so proceeded to drive forward, assuming the lifting crew had already de-rigged the container.

The rigger was approximately one meter above the ground and the 4th chain hook was still attached to the container and the crane, when the truck moved forward. The driver heard people shouting, and stopped the truck after it had moved around half a metre forward. Due to the truck movement, the rigger slipped off the ladder, sustaining bruising to his leg.
What went wrong?
Findings were:
- The supervisor did not provide the driver with an induction or briefing when he arrived at the yard.
- The Permit to Work for Working at Height indicated that a free standing work platform was to be used, but this was not used;
- The driver assumed that he was clear to drive forward;
- The Task Risk Assessment did not assess the risks introduced by or to the driver.
Actions/lessons learned
- Ensure clear and fully understood communication with third party plant operators – the truck driver in this case – before starting work;
- Ensure formal control of work, instructions, risk assessments and communications protocols are in place for third party drivers and other personnel;
- Consider keeping the driver away from the job completely until the lifting operations is complete. This prevents drive off and protects the driver from potential lifting issues impacting the driver’s cab.
Members may wish to refer to
Safety Event
Published: 16 December 2020
Download: IMCA SF 34/20
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.