Unprotected openings in floor grating – work stopped
What happened?
Two workers removed grating panels at height on a horizontal lay system, in order to gain access to lift points for further removal of a lateral walkway section. The removed grating created an open hole with the likelihood that someone could have fallen through it. None of the team involved were wearing the required PPE for working at height and no tool lanyards were used. The area around the horizontal lay system had not been barricaded. The activity was immediately stopped. No-one was injured; no dropped object resulted.

What went right – someone stopped the job!
What went wrong
- No-one involved in the activities perceived that the grating removal created a Work at Height hazard; the risks were underestimated.
What was the cause
- Inadequate or improper design of controls / barriers – several grating plates had to be removed in order to reach the structural beams needed to access the lift points;
- There was no Permit to Work in place;
- There were unclear or conflicting reporting relationships – information passed to the workers by a “Vessel Field Engineer” was accepted as actual instruction to do the job.
Lessons and actions
- Remember the importance of the Stop Work Authority – this should be used whenever an activity is deemed unsafe;
- Task seen as “routine” – routine activity sometimes leads us to disregarding or underestimating the risks associated with that activity;
- Ensure proper supervision, coordination, and a single point of control for work activities which are carried by two or more different work groups;
- Safety by design: safety aspects should be considered at design phase to ensure any potential hazards are considered, eliminated and/or relevant measures are taken against them.
Our member took the following actions
- Assessed the feasibility of installing accessible lifting points removing the need to remove grating plates;
- Looked at other project mobile equipment to assess how accessible lifting points are;
- Re-evaluated the need for a Permit to Work when certain activities are carried out in a changed work environment (such as grating removal that could create a WAH hazard);
- Ensured mobilization / demobilization plans include designation of single Responsible Person.
Members may wish to refer to
Safety Event
Published: 16 October 2023
Download: IMCA SF 24/23
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.