Vessel hit moored barge whilst turning
What happened?
Whilst turning in a river port, a vessel collided with a moored barge. The vessel`s port quarter grazed the starboard bow of the barge at around 0.1 knots. Damage to the vessel was not extensive, but the cost of repairing the damage to the barge was estimated to be US$350,000.
The incident occurred when the vessel was required to turn in a smaller turning basin than usual, in which there was a barge moored alongside a terminal within the turning radius of the vessel. The estimated turning area was 290 metres across; the barge was 17 metres wide and the vessel was 244 metres long. This left a very small margin of 29 metres.



What went wrong? What were the causes?
- The vessel turned in a smaller turning basin to save time and avoid traffic whilst a barge was moored alongside an oil terminal present in the vessel’s turning radius. The original plan was to turn in a larger turning basin further up the river;
- The bridge team did not challenge the Pilot`s orders or intervene;
- Risk seen as tolerable: the deviation from the current voyage plan for pilotage waters was based on pilot’s advice only and not properly assessed by the bridge team as it ought to have been;
- Complacency: the vessel crew had turned their vessel here before on several occasions, and had two pilots present on the bridge;
- Inadequate supervision: there was misjudgement of vessel movement, external forces (wind, current) and of the clearance to the barge.
What lessons were learned?
- Better communication with the Pilot and with mooring teams, regarding turning ranges to the shore/bank of the river and other vessels alongside the berth before starting turn;
- Avoid turning where there is only marginally enough room;
- Be more fully aware of vessel manoeuvring characteristics and inform the Pilot accordingly.
Members may wish to refer to:
Safety Event
Published: 18 April 2019
Download: IMCA SF 07/19
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.