Vessel hull damage due to quayside contact
What happened
In two separate incidents at Great Yarmouth in the UK, two vessels have sustained damage to hull plating and hull fenders through contact with damaged, missing or misaligned jetty fendering arrangements.
In one incident, a pad eye on the quayside edge made contact and penetrated the vessel hull plating. At the time of the incident, the vessel was experiencing strong beam winds gusting up to 47 knots, pushing the vessel onto the quayside. Contact with the furthest forward fendering squeezed it out of position and underneath the quay structure. This allowed the forward section of the hull to come into contact with the protruding pad eye. It has become apparent that the fender resting place on the quay structure must have been previously damaged, enabling the fender to slide around the quayside supporting column.
In the second incident, the vessel experienced damage to the hull fender and hull mounted fender frame. This was caused because there were no Yokohama fenders as expected, but instead large steel plates with sheets of rubber for the facing. The quayside location was exposed to the weather; the vessel experienced a heave of up to 2 metres, resulting in the wear down of the ship fender rubbing against the top edge of the quayside fender plate.

What went wrong
In the first incident, the securing arrangements (pad eye) for the Yokohama fender must have been damaged at some point, but this was not reported to the vessel. This resulted in the Yokohama fender being able to move away from the jetty column and thus offering no protection to the vessel’s hull.
In the second incident, the vessel Master was expecting Yokohama fenders. Instead the berth was fitted with metal, rubber faced plate fenders, which were not suitable for the hull layout of the vessel and resulted in damage to the vessel’s hull plating and fixed fenders.

In both incidents weather conditions were a contributing factor.
Lessons learned/actions
- Wherever possible obtain a berthing plan in good time so as to make a full appraisal of fendering, mooring and gangway arrangements and request any necessary changes or clarifications;
- Ensure a pre-arrival toolbox talk is conducted so that all personnel involved in the berthing operation are aware of both shore-side and onboard mooring and fendering arrangements;
- Remain aware of the weather conditions when approaching the berth and if not satisfied with the situation, abort the approach and/or request tug assistance if appropriate and available;
- If it becomes apparent that the intended berth is not suitable, abort the approach and inform the Pilot/Port Authority and request alternative arrangements;
- Once moored alongside, monitor weather conditions including tidal variations which may affect the vessel movement and potential contact with quayside fendering, obstructions or infrastructure;
- Keep this handy list near your passage plan folder to ensure that future port calls consider same information.
Members may wish to refer to:
Safety Event
Published: 4 March 2021
Download: IMCA SF 07/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.