Vessel Near Miss with wellhead
A vessel had a near miss with a wellhead within the 500m zone. The vessel Master was preoccupied and did not notice that the vessel was drifting close to the wellhead. The vessel missed the wellhead by less than 10 meters.
What was the cause?
Subject to further investigation:
- There was only one watchkeeper – the Master – on the bridge at the time. Company procedures for having two watchkeepers on the bridge at all times, were not followed;
- The client’s voyage procedures were not followed;
- The Master was preoccupied with change-over procedure which took attention away from the vessel’s movement;
- The Master assumed that the vessel was going more slowly than it actually was, and had no expectation that the vessel would drift so close to the wellhead.

Actions
Vessel Masters have overall authority for the health and safety of all personnel onboard the vessel, the safety of the vessel itself and it’s immediate environment.
- Ensure that watchkeeping procedures for bridge operations are strictly followed;
- Ensure that client voyage procedures are strictly followed;
- Ensure that there are sufficient trained, competent and rested people available at all times for watchkeeping;
- Follow COLREGs at all times;
- If a watch officer needs to leave post, ensure a suitable replacement is found before doing so.
Members may wish to refer to:
- Bow thruster room flooded during fresh water transfer operation [causes: negligent watch-keeping practice; Poor supervision of task; Poor handover or shift change procedures]
- MAIB: Two recent vessel collisions [MAIB conclusions: the two vessels collided because a proper lookout was not being kept on either vessel; complacency and poor watch-keeping practices]
- Vessel made contact with installation
Safety Event
Published: 19 January 2021
Download: IMCA SF 03/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.