Welding of shackles
A member has reported that in spite of clear work instructions and procedures to the contrary, shackles and hooks at the worksite were being regularly modified by welding. Rigging suppliers or individual worksites were carrying out welding modifications (mainly to shackles) after delivery from the manufacturer. This practice invalidates the manufacturer’s certificate and is potentially hazardous.
The welding of shackles (after delivery from manufacturer) has the effect of adversely altering the material properties and increases the risk of failure by various brittle modes. In addition to this increased risk, the nature of the failure is unpredictable, is not time dependant and cannot be prevented by inspection.
Our member recommends that all shackles and hooks that have been modified by welding should be removed from service. Equipment suppliers should be instructed not to modify or issue modified shackles or hooks for use on any worksite.


Safety Event
Published: 15 December 2010
Download: IMCA SF 08/10
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.