NTSB: Overturning of the Liftboat Kristin Faye
The National Transportation Safety Board (NTSB) of the United States has published Marine Accident Brief MAB 20-36 relating to the overturning of liftboat (small jack-up) Kristin Faye. Liftboats are three- or four-legged, self-propelled, self-elevating vessels typically servicing Gulf of Mexico offshore facilities (such as oil drilling platforms) by providing cranes and deck space.
What happened
On September 8, 2019, about 1015 local time, the liftboat Kristin Faye overturned while preparing to conduct work alongside a platform in the Gulf of Mexico, about 18 miles east of Venice, Louisiana. All three crewmembers abandoned the vessel and were rescued. One person suffered minor injuries during the evacuation. An estimated 120 gallons of diesel fuel were released. The vessel was declared a constructive total loss at an estimated US$750,000.

What was the cause
The probable cause determined by the NTSB was the company’s inadequate preload procedure that did not account for crane movements or the planned loads (weights) to be lifted, resulting in a “punch through” of one of the vessel’s three legs.
A full report can be found on the NTSB’s website here: www.ntsb.gov/investigations/AccidentReports/Reports/MAB2036.pdf
Safety Event
Published: 5 January 2021
Download: IMCA SF 02/21
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.