Collared eyebolts as lifting equipment
What happened?
NOPSEMA has published Alert 64 relating to the failure of collared eyebolts when used for lifting. A piece of equipment was being lifted during maintenance and repair, when one of the two collared eyebolts used to lift it, sheared. The piece of equipment, which weighed 21.7 tonnes, fell a distance of 1.2-1.8m. There were no injuries.
What were the causes of the incident?
NOPSEMA reports that the primary, immediate causes of the incident were as follows:
- The lifting equipment was configured such that the direction of pull was at an angle to the shaft of the eyebolt, so that a “fleet angle” from the vertical was created. Such an angular load reduced the Working Load Limit of the eyebolt to a significant degree;
- The collar of the eyebolt was not fully flush with the body of the piece of equipment being lifted, causing a sheering force due to the fleet angle to be applied to the shaft of the eyebolt, instead of the load being spread across the eyebolt and the surface of the equipment being lifted (as per design);
- A root cause identified was ineffective lift planning.
The full Safety Alert can be found on NOPSEMA’s website. Members may wish to refer to NOPSEMA’s earlier Safety Alert 59 Lifting and Rigging Plans.
Please also refer to Guidelines for lifting operations
Safety Event
Published: 15 June 2017
Download: IMCA SF 15/17
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.