Dropped object: Lay tower adjuster leg pin
What Happened
The securing pin from a Tiltable Lay System (TLS) adjuster leg, weighing 600 kg, fell 16m to deck. The incident occurred when the keeper plate bolts slackened off. No-one was in the immediate area below the adjuster leg at the time of the event and no-one was injured.
At the time of the incident there was an umbilical in the tower, but the umbilical was not being deployed. If deployment operations had been ongoing, then there would have been the potential for further consequences if the top tension were to have been above the survival capacity of one adjuster leg.



What went wrong?
- Investigations found that the planned maintenance and inspection regime was inadequate and unclear;
- During transits the tower was at times kept in operational position which could have allowed excess movement of the pin due to reduced load and increased dynamic movement;
- The design made it difficult to lubricate the pin adequately which may have caused excess friction.
Actions
- Following discussions with the manufacturer, the vessel returned to port for investigation, and during the transit to port, Structural Non-Destructive Testing (NDT) of pin connecting parts was undertaken on both legs to verify sufficient load capacity and seaworthiness;
- Adjuster leg pin put back in place and increased diameter anti-rotation locking key bolts were installed to provide additional bolt shear strength, as per manufacturers recommendation;
- Additional temporary bolt locking mechanisms (Loctite and locking wires) were installed on both adjuster leg pins locking key bolts to ensure vibration would not loosen the bolts before the permanent solution was ready;
- A check was made throughout the tower, of the tightness of all critical bolts and pins; new pin, bushing and lubricating lines were installed.
Longer term actions
- Tower to be in survival mode position during all transits according to the manufacturer’s recommendations;
- Planned maintenance requirements updated and clearly defined for accurate inspection criteria for critical pins and securing mechanisms;
- Bolt locking mechanisms installed in TLS critical pins (adjusters and TLS pivot) to ensure vibration will not loosen critical bolts.
Members may wish to refer to the following incidents:
- High potential dropped object near-miss: antenna fell to deck[an object came loose from a mast and fell to deck]
- High potential dropped object[an object fell 10m onto the main deck of a vessel during pipe spooling operations]
- Objects dropped from pipelay tower[bolts vibrated loose, resulting in the shaft being unrestrained and free to vibrate out along with the end cap]
Safety Event
Published: 22 May 2017
Download: IMCA SF 11/17
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.