High potential near miss: dropped object – buffer plate fell from crane boom
What happened?
During lifting operations with the main crane, a buffer plate fell from the crane boom. It fell approximately 10m, weighing 70 kg and was 90cm x 40cm. It landed inside the barriered off area on the back deck; there were no personnel nearby. Clearly this could have been a potential fatality had someone been struck by the plate. The purpose of the buffer plate is to be a buffer between the jib and the boom so the steel is not damaged.
What went wrong? What were the causes?
- The immediate cause was found to be that the bolts holding the buffer broke due to metal fatigue;
- The root cause was found to be inadequate or insufficient planned maintenance/inspection. Fatigue in the bolts had been allowed to develop over several years in operation as there had been no proper inspection of the bolts. It was not possible to see damage to the bolts during the visual inspections of the crane which were regularly carried out.

What lessons were learnt? What actions were taken?
- The bolts used subsequently to re-attach the buffer plate were increased in size from M12 to M14;
- Secondary securing of the buffer plate was installed to prevent it from falling;
- On all the members’ vessels with similar cranes, the planned maintenance system was modified to include maintenance/inspection of the buffer plate including bolts;
- A DROPS check of all cranes was made in order to assess for potential dropped objects during operation.
Members may wish to review the following incidents:
Safety Event
Published: 23 August 2017
Download: IMCA SF 21/17
IMCA Safety Flashes
Submit a Report
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding safetyreports@imca-int.com to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.
IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.
IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.